Artifact mimicking VT or VF

Electrical noise from patient movement, tremor or a loose electrode that looks like VT or VF on the monitor, while the heart is in an organized rhythm underneath.

Last updated

Live tracing25 mm/s · 10 mm/mV
Example ECG tracing of artifact mimicking VT or VF (simulated, lead II rhythm strip).

Example tracing, drawn by the lab's engine. Open the lab for a live, adjustable version.

At a glance

Patient
Awake, talking or moving, with a pulse
Underlying QRS
Narrow complexes keep marching through at a steady rate
Noise
Irregular, often fastest and largest in some leads only
Clean lead
A lead that does not use the moving electrode looks normal

All 5 criteria

Figures

Still images drawn by the lab's engine at 25 mm/s and 10 mm/mV, with the finding labeled. Select a figure to enlarge it.

Annotated, simulated ECG of artifact mimicking VT or VF. Lead II, about 3 seconds, zoomed.
Annotated still. Lead II, about 3 seconds, zoomed.
Simulated 12-lead ECG of artifact mimicking VT or VF, with a lead II rhythm strip.

Scroll sideways to see the whole tracing, or select it to enlarge.

12-lead. A full 12-lead of the rhythm, with a lead II rhythm strip.
Simulated 10-second rhythm strip of artifact mimicking VT or VF in lead II. Ten seconds of lead II.

Scroll sideways to see the whole tracing, or select it to enlarge.

Rhythm strip. Ten seconds of lead II.

What the heart is doing

The noise is not cardiac. A moving electrode changes its own potential, and every lead that uses that electrode records the change. The heart's activity continues underneath, so the real QRS complexes keep their timing.

Why it looks this way

This is artifact mimicking VT or VF because narrow QRS complexes keep marching through the noise at a steady rate, and the lead that does not use the moving electrode is clean.

Why it matters

Misread artifact leads to unneeded shocks, drugs and alarms. Always confirm a monitor rhythm against the patient and a pulse before treating; true VF needs immediate defibrillation and must not be dismissed as artifact.

What to look for

  • Look at the patient first: VF does not talk or brush its teeth.
  • Find the real QRS complexes and march them out with calipers through the noise.
  • Check other leads: noise from one electrode spares the lead that does not use it.
  • Compare with the pulse oximeter or arterial waveform, which keep a regular pulse.

Criteria

Patient
Awake, talking or moving, with a pulse
Underlying QRS
Narrow complexes keep marching through at a steady rate
Noise
Irregular, often fastest and largest in some leads only
Clean lead
A lead that does not use the moving electrode looks normal
Rate
The rate of the hidden QRS matches the pulse

Causes

  • Tremor (shivering, Parkinson disease, seizures)
  • Patient movement, brushing teeth, chest physiotherapy
  • Loose or dry electrodes
  • Transport vibration
  • Electrical interference

Can be mistaken for

Advanced Down to the ion channel

What the cells are doing

Pacemaker, atrial and ventricular action potentials, in step with the tracing above, with sodium, calcium and potassium moving through their channels.

Frequently asked questions

What are the ECG criteria for artifact mimicking VT or VF?

Patient: awake, talking or moving, with a pulse. Underlying QRS: narrow complexes keep marching through at a steady rate. Noise: irregular, often fastest and largest in some leads only. Clean lead: A lead that does not use the moving electrode looks normal. Rate: the rate of the hidden QRS matches the pulse.

How is artifact mimicking VT or VF identified on an ECG?

This is artifact mimicking VT or VF because narrow QRS complexes keep marching through the noise at a steady rate, and the lead that does not use the moving electrode is clean.

What can artifact mimicking VT or VF be mistaken for?

Ventricular fibrillation, coarse: no organized QRS anywhere and no pulse. Polymorphic ventricular tachycardia: wide complexes in every lead, no hidden narrow QRS. Torsades de pointes: twisting wide complexes, usually after a long QT.

What causes artifact mimicking VT or VF?

Common causes: tremor (shivering, Parkinson disease, seizures); patient movement, brushing teeth, chest physiotherapy; loose or dry electrodes; transport vibration; and electrical interference.