Paced

AV sequential (dual-chamber) pacing

A dual-chamber pacemaker paces the atrium, waits a set AV delay, then paces the ventricle, preserving the normal atrial-then-ventricular sequence.

Last updated

Live tracing25 mm/s · 10 mm/mV
Example ECG tracing of AV sequential (dual-chamber) pacing (simulated, lead II rhythm strip).

Example tracing, drawn by the lab's engine. Open the lab for a live, adjustable version.

At a glance

Rate
The programmed rate, perfectly regular
Pacing spikes
Two per beat: atrial, then ventricular
P waves
Follow the first spike
AV delay
Fixed, usually 120–200 ms between spikes

All 5 criteria

Figures

Still images drawn by the lab's engine at 25 mm/s and 10 mm/mV, with the finding labeled. Select a figure to enlarge it.

Annotated, simulated ECG of aV sequential (dual-chamber) pacing. Lead II, about 3 seconds, zoomed.
Annotated still. Lead II, about 3 seconds, zoomed.
Simulated 12-lead ECG of aV sequential (dual-chamber) pacing, with a lead II rhythm strip.

Scroll sideways to see the whole tracing, or select it to enlarge.

12-lead. A full 12-lead of the rhythm, with a lead II rhythm strip.
Simulated 10-second rhythm strip of aV sequential (dual-chamber) pacing in lead II. Ten seconds of lead II.

Scroll sideways to see the whole tracing, or select it to enlarge.

Rhythm strip. Ten seconds of lead II.

What the heart is doing

The device stimulates the right atrium, times an AV delay that stands in for the AV node, then stimulates the right ventricle. Ventricular activation spreads through muscle, widening the QRS.

Why it looks this way

This is AV sequential pacing because each beat has two spikes: one before the P wave and, after a fixed delay, one before a wide QRS.

Why it matters

Normal dual-chamber function. Keeping the atrial contribution to filling improves cardiac output compared with ventricular pacing alone. Assess capture of both chambers.

What to look for

  • Two spikes in each cycle, a constant distance apart.
  • A P wave after the first spike and a wide QRS after the second.
  • Check that both spikes capture on every beat.

Criteria

Rate
The programmed rate, perfectly regular
Pacing spikes
Two per beat: atrial, then ventricular
P waves
Follow the first spike
AV delay
Fixed, usually 120–200 ms between spikes
QRS
Wide, LBBB-like, after the second spike

Causes

  • AV block with sinus node dysfunction
  • Complete heart block in a patient in sinus rhythm
  • Symptomatic bradycardia needing AV synchrony

Can be mistaken for

Advanced Down to the ion channel

What the cells are doing

Pacemaker, atrial and ventricular action potentials, in step with the tracing above, with sodium, calcium and potassium moving through their channels.

Frequently asked questions

What are the ECG criteria for AV sequential (dual-chamber) pacing?

Rate: the programmed rate, perfectly regular. Pacing spikes: two per beat: atrial, then ventricular. P waves: follow the first spike. AV delay: fixed, usually 120–200 ms between spikes. QRS: wide, LBBB-like, after the second spike.

How is AV sequential (dual-chamber) pacing identified on an ECG?

This is AV sequential pacing because each beat has two spikes: one before the P wave and, after a fixed delay, one before a wide QRS.

What can AV sequential (dual-chamber) pacing be mistaken for?

Ventricular pacing alone: one spike per beat and no paced P wave. Atrial pacing: one spike per beat followed by a narrow QRS. Sinus rhythm with LBBB and artifact: no consistent spikes.

What causes AV sequential (dual-chamber) pacing?

Common causes: AV block with sinus node dysfunction; complete heart block in a patient in sinus rhythm; and symptomatic bradycardia needing AV synchrony.

Sources

This page does not list page-specific sources yet.

Every source the site cites, with links

Report a correction

Tell us what looks wrong, ideally with a source. Reports go to a private tracking list; you get a ticket number.

Up to 2000 characters.

What is stored