Leads and axis

Right-sided and posterior leads

V4R and V7–V9

The standard 12 leads miss the right ventricle and the back of the left ventricle. Moving chest electrodes to the right (V4R) or around the back (V7–V9) fills those gaps when an inferior or posterior infarction is suspected.

Last updated

Live tracing25 mm/s · 10 mm/mV
Example ECG tracing of right-sided and posterior leads (simulated).

Example tracing, drawn by the lab's engine. Open the lab for a live, adjustable version.

At a glance

V4R
5th ICS, right midclavicular line
V7
Left posterior axillary line
V8
Tip of the left scapula
V9
Left paraspinal

All 6 key numbers

Figures

Still images drawn by the lab's engine at 25 mm/s and 10 mm/mV, with the finding labeled. Select a figure to enlarge it.

Annotated, simulated ECG of right-sided and posterior leads. Leads V2, V3 and V8, the same beat, zoomed, with the finding labeled. Labels: Tall R; T upright at its end.
Annotated still. Leads V2, V3 and V8, the same beat, zoomed, with the finding labeled.
Simulated 12-lead ECG of right-sided and posterior leads, with a lead II rhythm strip. Tinted blue, reciprocal ST depression: V1, V2, V3.

Scroll sideways to see the whole tracing, or select it to enlarge.

12-lead. A full 12-lead with a lead II rhythm strip. Blue tint: reciprocal ST depression in V1, V2 and V3. V7–V9 are not on a standard 12-lead: the still shows V8, where the elevation itself is seen.

Right-sided leads

Place the chest electrodes in the mirror-image positions on the right chest. V4R, in the fifth intercostal space in the right midclavicular line, is the most useful. ST elevation there in an inferior infarction points to proximal right coronary occlusion with right ventricular involvement, which matters because those patients depend on preload.

Posterior leads

V7 sits in the left posterior axillary line, V8 at the tip of the scapula and V9 beside the spine, all level with V6. Posterior infarction shows as ST depression in V1–V3 on the standard ECG, the mirror image of ST elevation that V7–V9 record directly.

How to read it

  • Record V4R in every inferior ST elevation.
  • Record V7–V9 when V1–V3 show horizontal ST depression with upright T waves.
  • Label the printout so the leads are not read as standard ones.

Pitfalls

  • Right ventricular ST elevation is transient and can resolve within hours.
  • Posterior ST elevation is small because the electrodes are far from the heart; use the lower threshold.

Key numbers

V4R
5th ICS, right midclavicular line
V7
Left posterior axillary line
V8
Tip of the left scapula
V9
Left paraspinal
Posterior STE
≥ 0.5 mm in V7–V9
Right ventricular STE
≥ 0.5 mm in V4R

Advanced Down to the ion channel

What the cells are doing

Pacemaker, atrial and ventricular action potentials, in step with the tracing above, with sodium, calcium and potassium moving through their channels.

Frequently asked questions

Right-sided and posterior leads: what is the key idea?

The standard 12 leads miss the right ventricle and the back of the left ventricle. Moving chest electrodes to the right (V4R) or around the back (V7–V9) fills those gaps when an inferior or posterior infarction is suspected.

Right-sided and posterior leads: what are the key numbers?

V4R: 5th ICS, right midclavicular line; V7: Left posterior axillary line; V8: Tip of the left scapula; V9: Left paraspinal; Posterior STE: ≥ 0.5 mm in V7–V9; Right ventricular STE: ≥ 0.5 mm in V4R.

Right-sided and posterior leads: how do you apply it to an ECG?

Record V4R in every inferior ST elevation. Record V7–V9 when V1–V3 show horizontal ST depression with upright T waves. Label the printout so the leads are not read as standard ones.

Right-sided and posterior leads: what are the common pitfalls?

Right ventricular ST elevation is transient and can resolve within hours. Posterior ST elevation is small because the electrodes are far from the heart; use the lower threshold.