Junctional & SVT
Accelerated junctional rhythm
The AV junction fires at 60–100/min and takes control from the sinus node. The QRS is narrow; a retrograde P wave may come before the QRS, hide within it or follow after the QRS.
Last updated

Example tracing, drawn by the lab's engine. Open the lab for a live, adjustable version.
At a glance
- Rate
- 60–100/min
- Rhythm
- Regular
- P waves
- Retrograde (inverted in II): before the QRS (as here), hidden within it, or after it
- PR interval
- < 120 ms, only when the retrograde P precedes the QRS
Figures
Still images drawn by the lab's engine at 25 mm/s and 10 mm/mV, with the finding labeled. Select a figure to enlarge it.
What the heart is doing
Enhanced automaticity makes junctional cells fire faster than the sinus node. Impulses travel down to the ventricles and back into the atria, inverting the P; its timing sets where it falls.
Why it looks this way
This is an accelerated junctional rhythm because it is regular at 60–100/min with narrow QRS complexes and retrograde P waves, here just before the QRS with a PR under 120 ms.
Why it matters
Usually well tolerated and transient; treat the cause instead of the rhythm. In a patient taking digoxin, assume toxicity until proven otherwise.
What to look for
- A normal-rate, regular narrow rhythm with no upright P before the QRS; look before, within and after it.
- When a P wave precedes the QRS, measure the PR: under 120 ms points to the junction, not a low atrial focus.
- Onset and offset are gradual, as with other automatic rhythms.
Criteria
- Rate
- 60–100/min
- Rhythm
- Regular
- P waves
- Retrograde (inverted in II): before the QRS (as here), hidden within it, or after it
- PR interval
- < 120 ms, only when the retrograde P precedes the QRS
- QRS
- Narrow (< 120 ms)
Causes
- Digoxin toxicity
- Inferior myocardial infarction
- After cardiac surgery
- Myocarditis
- Reperfusion after infarction
- Beta-agonist or catecholamine excess
Can be mistaken for
- Normal sinus rhythm — P waves upright in II with a PR of at least 120 ms Compare
- Ectopic atrial rhythm — abnormal P shape or axis before the QRS, with PR ≥ 120 ms Compare
- Accelerated idioventricular rhythm — wide QRS Compare
Advanced Down to the ion channel
What the cells are doing
Pacemaker, atrial and ventricular action potentials, in step with the tracing above, with sodium, calcium and potassium moving through their channels.
Frequently asked questions
What are the ECG criteria for accelerated junctional rhythm?
Rate: 60–100/min. Rhythm: regular. P waves: retrograde (inverted in II): before the QRS (as here), hidden within it, or after it. PR interval: < 120 ms, only when the retrograde P precedes the QRS. QRS: narrow (< 120 ms).
How is accelerated junctional rhythm identified on an ECG?
This is an accelerated junctional rhythm because it is regular at 60–100/min with narrow QRS complexes and retrograde P waves, here just before the QRS with a PR under 120 ms.
What can accelerated junctional rhythm be mistaken for?
Normal sinus rhythm: P waves upright in II with a PR of at least 120 ms. Ectopic atrial rhythm: abnormal P shape or axis before the QRS, with PR ≥ 120 ms. Accelerated idioventricular rhythm: wide QRS.
What causes accelerated junctional rhythm?
Common causes: digoxin toxicity; inferior myocardial infarction; after cardiac surgery; myocarditis; reperfusion after infarction; and beta-agonist or catecholamine excess.
Sources
This page does not list page-specific sources yet.
Every source the site cites, with links