Chamber enlargement

Right atrial enlargement

An enlarged right atrium produces a tall, peaked P wave in the inferior leads, while the P-wave width stays normal.

Last updated

Live tracing25 mm/s ยท 10 mm/mV
Example ECG tracing of right atrial enlargement (simulated).

Example tracing, drawn by the lab's engine. Open the lab for a live, adjustable version.

At a glance

P wave in II
> 2.5 mm tall, peaked
P wave in V1
Initial positive part > 1.5 mm
P duration
Normal (< 120 ms)
Leads
Best seen in II, III, aVF

Figures

Still images drawn by the lab's engine at 25 mm/s and 10 mm/mV, with the finding labeled. Select a figure to enlarge it.

Annotated, simulated ECG of right atrial enlargement. Leads II and V1, the same beat, zoomed, with the finding labeled. Labels: Tall, peaked P; Prominent initial P.
Annotated still. Leads II and V1, the same beat, zoomed, with the finding labeled.
Simulated ECG comparison. Lead II: a normal beat beside right atrial enlargement, at the same scale.
Comparison. Lead II: a normal beat beside right atrial enlargement, at the same scale.
Simulated 12-lead ECG of right atrial enlargement, with a lead II rhythm strip.

Scroll sideways to see the whole tracing, or select it to enlarge.

12-lead. A full 12-lead with a lead II rhythm strip.

What the heart is doing

The right atrium depolarizes first, with forces pointing downward and forward. More right atrial muscle enlarges this early component, which stacks on top of the left atrial part.

Why it looks this way

This is right atrial enlargement because the P wave in lead II is peaked and taller than 2.5 mm, with a normal duration.

Why it matters

A sign of right heart pressure or volume load, most often from lung disease. Treatment is directed at the cause.

What to look for

  • In lead II, the P wave is taller than two and a half small boxes and pointed.
  • The P wave is not widened, which separates it from left atrial enlargement.
  • Look for right axis deviation or right ventricular hypertrophy alongside it.

Criteria

P wave in II
> 2.5 mm tall, peaked
P wave in V1
Initial positive part > 1.5 mm
P duration
Normal (< 120 ms)
Leads
Best seen in II, III, aVF

Causes

  • Chronic lung disease
  • Pulmonary hypertension
  • Pulmonary embolism
  • Tricuspid valve disease
  • Congenital heart disease

Can be mistaken for

Advanced Down to the ion channel

What the cells are doing

Pacemaker, atrial and ventricular action potentials, in step with the tracing above, with sodium, calcium and potassium moving through their channels.

Frequently asked questions

What are the ECG criteria for right atrial enlargement?

P wave in II: > 2.5 mm tall, peaked. P wave in V1: initial positive part > 1.5 mm. P duration: normal (< 120 ms). Leads: best seen in II, III, aVF.

How is right atrial enlargement identified on an ECG?

This is right atrial enlargement because the P wave in lead II is peaked and taller than 2.5 mm, with a normal duration.

What can right atrial enlargement be mistaken for?

Sinus tachycardia: P waves grow taller with sympathetic drive. Hypokalemia: prominent P waves with U waves and flat T waves. Left atrial enlargement: wide notched P wave of normal height.

What causes right atrial enlargement?

Common causes: chronic lung disease; pulmonary hypertension; pulmonary embolism; tricuspid valve disease; and congenital heart disease.

Sources

This page does not list page-specific sources yet.

Every source the site cites, with links

Report a correction

Tell us what looks wrong, ideally with a source. Reports go to a private tracking list; you get a ticket number.

Up to 2000 characters.

What is stored